- Bastian Wiggershaus
- Eric Franke
- Carla Vogt
- Titel
- Total reflection x-ray fluorescence analysis of trace elements in highly saline samples
- Zitierfähige Url:
- https://nbn-resolving.org/urn:nbn:de:bsz:105-qucosa2-1041684
- Quellenangabe
- X-ray spectrometry
Erscheinungsjahr: 2025
Jahrgang: 54
Heft: 2
Seiten: 193-202
ISSN: 1097-4539 - Erstveröffentlichung
- 2024
- Abstract (EN)
- The reliable trace analysis of high-purity chemicals and environmentally relevant samples is more important than ever and has led to the development of novel analytical methods. Total reflection x-ray fluorescence (TXRF) analysis is an increasingly known method for the determination of heavy metals at low concentration levels in environmental and industrial sample systems. However, there is still a need for optimization to obtain fast and precise results, especially for highly saline samples like brines and salts used in battery production or sea water. In this study, multi-element standard solutions containing analytes like Co, Cr, Cu, Fe, Mn, Ni, or Zn in a concentration range between 0.1 and 1 mg/L were analyzed in the matrices lithium carbonate (Li2CO3) and artificial seawater (ASW) containing 1000 mg/L Li and 24,000 mg/L NaCl, respectively, leading to matrix-analyte ratios of up to 240,000:1. Different sample preparation methods were compared in order to achieve the highest possible repeatability (1) and signal-to-noise ratios (2) with the least amount of time (3). Various parameters such as sample volume, drying conditions, time, temperature and additive concentration were varied. The relative standard deviation (RSD%) was used as a measure of repeatability for three replicates per sample. For lithium carbonate, a method with a preparation time of only 2 min and a measurement time of 500 s could be developed, which allowed to obtain RSD% well below 5%, a high linearity (R2 > 0.99) and limits of detection (LOD) in the range of 30 μg/L to 60 μg/L for most elements. Seawater analysis could be optimized with respect to signal-to-noise ratio, whereby the Kα-line of the internal standard (Ga) was used for evaluation and the use of a desiccator was found to yield the best results.
- Andere Ausgabe
- Total reflection x-ray fluorescence analysis of trace elements in highly saline samples
DOI: 10.1002/xrs.3448 - Freie Schlagwörter (DE)
- Analyse, Chemische Analyse, Methode, Spurenanalyse, Forschungsmethode, Totalreflexionsröntgenfluoreszenzanalyse, Meerwasser, Multielementanalyse, Umweltanalytik
- Freie Schlagwörter (EN)
- highly saline matrix, lithium analysis, sample preparation, sea water analysis, trace element analysis, TXRF
- Klassifikation (DDC)
- 540
- Normschlagwörter (GND)
- Totalreflexionsröntgenfluoreszenzanalyse
- Meerwasser
- Multielementanalyse
- Multielementanalyse
- Verlag
- Wiley, New York
- Sonstige beteiligte Institution
- Technische Universität Bergakademie Freiberg, Freiberg
- Version / Begutachtungsstatus
- publizierte Version / Verlagsversion
- URN Qucosa
- urn:nbn:de:bsz:105-qucosa2-1041684
- Veröffentlichungsdatum Qucosa
- 27.04.2026
- Dokumenttyp
- Artikel
- Sprache des Dokumentes
- Englisch
- Lizenz / Rechtehinweis
CC BY-NC-ND 4.0